Industrial Cables Manufacturers

Description

Hyphen today is one of the most preferred and trusted name in House wires. It has emerged as first choice and gained reputation & confidence of consultants, architects and real estate developers.

Hyphen has built up a reputation for commercial foresight and solid integrity. Tested and supervised by experienced engineers in sophisticated labs, our wires have earned a name for themselves in both Indian and international markets.


Specification:
Click Here to view Specification for House Wiring and industrial cables.


Product Details

Specifications

Reference Specification IS : 694-1990
Voltage Grade 1100 Volts
Conductor Aluminium: E.C. Grade Aluminium as per flexibility class 1 &2 of IS : 8130-1984
Copper: Electrolytic Grade Bare Annealed Copper as per flexibility class 1,2 & 5 of IS : 8130-1984
Insulation PVC Type A of IS : 5831-1984 for Conductor Temperature 700C
PVC Type C of IS : 5831-1984 for Conductor Temperature 850C
Colour of Insulation Cable for fixed installation
Single Core Wire & Cables Red, Yellow, Blue, Grey, Green, White or any colour as per customer's requirement.
Two Core Cables Red & Black
Three Core Cables Red, Yellow & Blue
Four Core Cables Red, Yellow, Blue & Black
Colour of Insulation Flexible Wires, Cables & Cords
Single Core Wires & Cables Red, Yellow, Blue, Black, Grey, Green, White or any colour as per customer's requirement
Two Core Cables
Three Core Cables Red, Black & Green
Four Core Cables
Five Core Cables
Sheath PVC Type ST-1 of IS : 5831-1984 for Conductor Temperature 700C
PVC Type ST-2 of IS : 5831-1984 for Conductor Temperature 850C
1.) Non Weatherproof Cables : Black or any colour as per Customer's requirement
2.) Weatherproof Cables : Black Only

Other Details

Tolerence

Tolerance on Thickness of Insulation

Tolerance on Thickness of Insulation The smallest of the measured values of thickness of insulation shall not fall below the nominal value specified in the relevant tables by more than (0.1 mm + 0.1 t1)
Where t1 = Nominal Thickness of Insulation in mm.
Tolerance of Thickness of Sheath The smallest of the measured values of thickness of sheath shall not fall below the nominal value specified in the relevant tables by more than (0.2 mm + 0.2 ts)
Where ts = Nominal Thickness of Sheath in mm.
Laying up of core for 2, 3 and 4 core cables The cores are be laid together with a suitable right hand lay.
Flat 2 and 3 core cable The cores are laid side by side. In case of 2 core flat cables with Earth continuity conductor the core and the E.C.C are laid side by side in the same plane with E.C.C. occupying the central position.
Hyphen Wires are made form the purest form of Copper & PVC Compound with rigorous testing at every stage by our team of qualified engineers. FR/FRLS characteristics like oxygen index, temperature index, smoke density, Halogen %age & Flammability etc.are maintained as per ASTM / IEC Standards.